1.5 CONNECT THE LABELLED WIRES
TO
THE THERMOSTAT
1.
Connect
the
system wires
to
the
thermostat terminals according
to
the
wiring
diagram shown
in
section
1.6.
2.
Make
sure
that the wires
are
pushed
well
back into
the
wall.
3.
If
you
own
a
CT240
telephone controller,
refer
to
section
6.1
for
connection.
1.6
WIRING
DIAGRAMS
The
TH141
thermostat
is
compatible
with
most heating and
air
conditioning systems.
Multi-level heating
and
air
conditioning systems, Milivolt control heating systems,
heat
pumps
and
baseboard heating
units
are
not
compatible
with
this
thermostat.
Baseboard
units
can
be connected using a
24
V
relay.
1.6.1
2-WIRE
HEATING SYSTEM
1.
Connect
the
heating relay
to
terminal
W.
2.
Connect
the
24
V transformer
to
terminal
Rh.
In
this case,
the
order of connection
is
unimportant.
l
r--------Rh
--J
G
HEATING
1---
w
Rc
y
G
X
C
4