Sequence of operations
- Start immobilizer self-diagnosis => Page 140 .
-> Display on VAS 5051:
- From list -1- select diagnosis function "08 - Reading measured value block".
-> Display on VAS 5051:
1 - Enter display group
- Use keypad -2- to enter required three-digit display group number
=>List of display groups, Page 148 and confirm entry by touching Q key.
-> Display on VAS 5051:
1 - Reading measured value block
2 - Display zone 1
Display zone 2
Display zone 3
Display zone 4
3 - Display group X
Notes:
◆ Display remains blank if a display zone is not used.
◆ Proceed as follows to switch to a different display group:
Display group VAS 5051
Up Press s key
Audi A3 1997 ➤
Electrical system Self-diagnosis - Edition 02.2002
5.8 - Reading measured value block 147