Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
8.5 - Fault table
Notes:
◆ Faults occurring in monitored sensors or components are stored in fault memory together with an indication
of the type of fault.
◆ The fault table is arranged according to the 5-digit fault codes on the left.
◆ All static and sporadic faults are stored in the fault memory:
A fault is recognised as being static if it is present for at least 2 seconds. If a fault is then no longer present,
it is stored as being sporadic and "sporadic" also appears on display.
◆ After switching on ignition, all faults present are set to sporadic and only stored as being static if they are
still present after checking.
◆ Sporadic faults are erased if they do not re-occur in the course of 50 driving cycles (ignition on for at least
5 minutes, vehicle speed greater than 30 km/h).
◆ Do not immediately replace components indicated as being defective by VAS 5051, but rather: Start by
checking wiring and connectors to these components in line with current flow diagram. Also use current flow
diagram to check earth connections. This is particularly important if faults are output as being "sporadic".
◆ On completion of repair work, fault memory is to be interrogated again and erased.
Display on VAS 5051 Possible cause of trouble Fault remedy
00532
Supply voltage
- Signal too low - Open circuit in wiring or short circuit
in power supply
- Use current flow diagram to perform
fault-finding
00625
Speed signal
- Implausible signal - Fault is set if vehicle-speed signal is
implausible (e.g. 500 km/h); occurs,
for example, in the event of loose
contact in wiring
- Use current flow diagram to perform
fault-finding
01543
Parking aid warning buzzer -H15
- Short to positive
- Open circuit/short to earth
- Open circuit in wiring or short circuit
between -H15 and control unit
- Use current flow diagram to perform
fault-finding
- -H15 defective - Replace -H15
Display on VAS 5051 Possible cause of trouble Fault remedy
01545
RL parking aid sender -G203
- Short to positive
- Open circuit/short to earth
- Open circuit in wiring or short circuit
between -G203 and control unit
- Use current flow diagram to perform
fault-finding
- Defective component
- Implausible signal
- -G203 defective - Replace -G203
01546
RL, ctr, parking aid sender
-G204
- Short to positive
- Open circuit/short to earth
- Open circuit in wiring or short circuit
between -G204 and control unit
- Use current flow diagram to perform
fault-finding
- Implausible signal
- -G204 defective - Replace -G204
Display on VAS 5051 Possible cause of trouble Fault remedy
01547
RR, ctr, parking aid sender
-G205
Audi A3 1997 ➤
Electrical system Self-diagnosis - Edition 02.2002
212 01 - Self-diagnosis