Configuration Note 5. Gateway Configuration
Version 6.8 33 Mediant 1000B
5.17 Step 15: Modify Parameters in the AdminPage
This step describes how to modify parameters on the AdminPage.
To modify parameters on the AdminPage:
1. Open the 'AdminPage' page at the following URL (case-sensitive):
http://<gateway’s IP address>/AdminPage
2. Click on the ini Parameters menu option.
3. In the ‘Parameter Name’ field, enter " ISDNIBehavior ".
2. In the ‘Enter Value’, enter 1073741824”.
4. Click Apply New Value.
5. In the Output Window, confirm that all the fields have been correctly updated.
6. Repeat Steps 3 to 5 for the following Parameter Names and appropriate Enter Values.
ECNLPMode: “1”
EnableMWI: “1”
SubscriptionMode: “1”
Figure 5-21: AdminPage