EasyManua.ls Logo

AudioCodes MediaPack MP-112 - Table 5-15: Ini File Coder Group Parameters

AudioCodes MediaPack MP-112
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MediaPack SIP
MediaPack SIP User’s Manual 92 Document #: LTRT-65405
many coder payloads are combined into one RTP (voice) packet.
Note 1: The ptime packetization period depends on the selected coder name.
Note 2: If not specified, the ptime gets a default value.
Note 3: The ptime specifies the maximum packetization time the gateway can receive.
5. Repeat steps 3 and 4 for the second to fifth coders (optional).
6. Repeat steps 2 to 5 for the second to forth coder groups (optional).
7. Click the Submit button to save your changes.
8. To save the changes so they are available after a power fail, refer to Section
5.9 on page
161.
Note: In the current version, only the ptime of the first coder is sent in the SDP
section of the INVITE message.
Table 5-15: ini File Coder Group Parameters
Parameter Description
CoderName_ID
Coder list for Profiles (up to five coders in each group).
The CoderName_ID parameter (ID from 1 to 4) provides groups of coders that can be
associated with IP or Tel profiles.
You can select the following coders:
g711Alaw64k – G.711 A-law.
g711Ulaw64k – G.711 µ-law.
g7231 – G.723.1 6.3 kbps (default).
g7231r53 – G.723.1 5.3 kbps.
g726 – G.726 ADPCM 32 kbps (Payload Type = 2).
g729 G.729A.
g729_AnnexB – G.729 Annex B.
The RTP packetization period (ptime, in msec) depends on the selected Coder name,
and can have the following values:
G.711 family – 10, 20, 30, 40, 50, 60, 80, 100, 120 (default=20).
G.729 family – 10, 20, 30, 40, 50, 60 (default=20).
G.723 family – 30, 60, 90 (default = 30).
G.726 family – 10, 20, 30, 40, 50, 60, 80, 100, 120 (default=20)
Note: If the coder G.729 is selected, the gateway includes ‘annexb=no’ in the SDP of the
relevant SIP messages. If G.729 Annex B is selected, ‘annexb=yes’ is included. An
exception to this logic is when the remote gateway is a Cisco device (IsCiscoSCEMode).
ini file note 1: This parameter (CoderName_ID) can appear up to 20 times (five coders
in four coder groups).
ini file note 2: The coder name is case-sensitive.
ini file note 3: Enter in the format: Coder,ptime.
For example, the following three coders belong to coder group with ID=1:
CoderName_1 = g711Alaw64k,20
CoderName_1 = g711Ulaw64k,40
CoderName_1 = g7231,90