2.2. Short description
AUMA multi-turn actuators SA 07.2 SA 16.2/SAR 07.2 SAR 16.2 are driven by
an electric motor and are capable of withstanding thrust in combination with output
drive type A. For manual operation, a handwheel is provided. Switching off in end
positions may be either by limit or torque seating. Actuator controls are required to
operate or process the actuator signals.
Actuator controls
AC 01.2 actuator controls are used to operate AUMA actuators and are supplied
ready for use.The actuator controls may be mounted directly to the actuator or
separately on a wall bracket.
The functions of the actuator controls include standard valve control in OPEN-CLOSE
duty, positioning, process control, logging of operating data, diagnostic functions
right through control via various interfaces (e.g. Fieldbus, Ethernet and HART).
Local controls/
AUMA CDT
Operation, setting, and display can be performed directly at the actuator controls or
alternatively from REMOTE via a communication interface.
When set to local control, it is possible to
operate the actuator via the local controls (push buttons and display) and perform
settings (contents of these instructions).
read in or out data or modify and save settings via AUMA CDT software (ac-
cessory), using a computer (laptop or PC).The connection between computer
and actuator controls is wireless via Bluetooth interface (not included in these
instructions).
Intrusive - Non-Intrusive
Intrusive version (control unit: electromechanical):
Limit and torque setting is performed via switches in the actuator.
Non-Intrusive version (control unit: electronic):
Limit and torque setting is performed via the controls, without removal of actu-
ator or actuator controls covers. For this purpose, the actuator is equipped with
an MWG (magnetic limit and torque transmitter), also capable to supply analogue
torque feedback signals/torque indication and analogue position feedback sig-
nals/position indication at the actuator controls output.
11
SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit: electronic (MWG)
AC 01.2 Non-Intrusive EtherNet/IP Identification

Table of Contents

Other manuals for AUMA SA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUMA SA Series and is the answer not in the manual?

AUMA SA Series Specifications

General IconGeneral
Torque range10 Nm to 32, 000 Nm
Protection classIP68
Ambient temperature+70°C
Voltage24V DC
CommunicationPROFIBUS DP, MODBUS RTU, Foundation Fieldbus
CertificationsATEX, IECEx, CSA, GOST, SIL
ControlLocal, Remote, Bus (PROFIBUS, MODBUS)