Figure 61: Function check
For further information, please also refer to <Corrective action>.
Maintenance required (S0010)
The S0010 indication shows maintenance indications according to NAMUR
recommendation NE 107.
If such an indication has occurred, the display shows S0010:
the number of indications occurred
a blinking square with an oilcan after approx. 3 seconds
Figure 62: Maintenance required
For further information, please also refer to <Corrective action>.
Failure (S0011)
The S0011 indication shows the causes of the failure indication according to NAMUR
recommendation NE 107.
If such an indication has occurred, the display shows S0011:
the number of indications occurred
a blinking circle with a cross after approx. 3 seconds
Figure 63: Failure
For further information, please also refer to <Corrective action>.
52
SA 07.2 SA 16.2 / SAR 07.2 SAR 16.2 Control unit: electronic (MWG)
Indications AC 01.2 Non-Intrusive EtherNet/IP

Table of Contents

Other manuals for AUMA SA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUMA SA Series and is the answer not in the manual?

AUMA SA Series Specifications

General IconGeneral
Torque range10 Nm to 32, 000 Nm
Protection classIP68
Ambient temperature+70°C
Voltage24V DC
CommunicationPROFIBUS DP, MODBUS RTU, Foundation Fieldbus
CertificationsATEX, IECEx, CSA, GOST, SIL