EasyManua.ls Logo

AUMA SAR 07.1 - SAR 30.1 - Setting the Mechanical Position Indicator (Option); Closing the Switch Compartment

AUMA SAR 07.1 - SAR 30.1
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
31
18. Setting the mechanical position indicator (option)
.
Place indicator disc on shaft.
.
Move valve to end position CLOSED.
.
Turn lower indicator disc (figure 41) until symbol CLOSED is in alignment
with the mark on the cover (figure 42).
.
Move actuator to end position OPEN.
.
Hold lower indicator disc CLOSED in position and turn upper disc with
symbol OPEN until it is in alignment with the mark on the cover.
Indicator disc rotates approximately 180° to 230° at full travel from OPEN to
CLOSED or vice v
ersa. For this purpose, a suitable reduction gearing was
installed in our works.
If the turns per stroke of the actuator are changed at a later date, the reduc-
tion gearing may have to be exchanged.
19. Closing the switch compartment
.
Clean sealing faces of housing and cover
.
Check whether O-ring is in good condition.
.
Apply a thin film of non-acidic grease to the sealing faces.
.
Replace cover on switch compartment and fasten bolts evenly crosswise.
Check the multi-turn actuator for damage to paint finish. If
dama
ge to paint-finish has occurred after mounting, it has to
be touched up to avoid corrosion.
Figure 41
Indicator disc
Figure 42
Mark

Table of Contents