Grease change is performed during maintenance
- Generally after 4 to 6 years for modulating duty.
- Generally after 6 to 8 years if operated frequently (open-close duty).
- Generally after 10 to 12 years if operated infrequently (open-close duty).
We recommend replacing the seals when changing the grease.
Additional lubrication of the gear housing is not required during operation.
12.3. Disposal and recycling
Our devices have a long lifetime. However, they have to be replaced at one point in
time.The devices have a modular design and may, therefore, easily be separated
and sorted according to materials used, i.e.:
various metals
plastics
greases and oils
The following generally applies:
Greases and oils are hazardous to water and must not be released into the
environment.
Arrange for controlled waste disposal of the disassembled material or for sep-
arate recycling according to materials.
Observe the national regulations for waste disposal.
75
SA 07.2 SA 16.2/SAR 07.2 SAR 16.2 Control unit: electronic (MWG)
AC 01.2 Non-Intrusive HART Servicing and maintenance

Table of Contents

Other manuals for AUMA SAR 07.2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AUMA SAR 07.2 and is the answer not in the manual?

AUMA SAR 07.2 Specifications

General IconGeneral
BrandAUMA
ModelSAR 07.2
CategoryController
LanguageEnglish

Related product manuals