Home
AUMA
Controller
SAR 07.2
AUMA SAR 07.2 Manual
4
of 1
of 1 rating
52 pages
Give review
Manual
Specs
To Next Page
To Next Page
Loading...
Multi-tur
n actuators
SA 07.2
–
SA 16.2/SAR 07.2
–
SAR 16.2
SAEx 07.2
–
SAEx 16.2/SAREx 07.2
–
SAREx 16.2
with actuator controls
A
C 01.2-SIL/A
CExC 01.2-SIL
SIL v
ersion
Functional Saf
ety
Manual
2
Table of Contents
Default Chapter
2
Table of Contents
2
1 Terminology
4
Abbreviations and Concepts
4
Sa 16.2/Sar 07.2
4
2 Application and Validity
6
Range of Application
6
Standards
6
Valid Device Types
6
Architecture (Actuator Sizing)
7
3 Architecture, Configuration and Applications
7
Configuration (Setting)/Version
8
Applications (Environmental Conditions)
9
Safety Functions
11
Safety Instrumented System Including an Actuator
11
4 Safety Instrumented Systems and Safety Functions
11
Redundant System Architecture
12
Safe Inputs and Outputs
12
Examples of Applications
13
System Representation
14
Installation
15
5 Installation, Commissioning and Operation
15
Commissioning
16
Decommissioning
17
Lifetime
17
Operation
17
6 Indications on Display
18
Status Indications on SIL Functions
18
Backlight
19
SIL Configuration Warning
19
7 Signals
20
Signals Via SIL Module
20
SIL Fault Signal Via Standard Controls Display (for Troubleshooting Support)
20
Signal Via Fieldbus of Standard Controls
21
Status Signals Via Output Contacts (Digital Outputs) of Standard Controls
21
Internal Actuator Monitoring with Control Via Standard Controls
23
Partial Valve Stroke Test (PVST): Execute
23
Safety Equipment: Check
23
Tests and Maintenance
23
Proof Test (Verification of Safe Actuator Function)
24
Safe ESD Safety Operation (Safe OPENING/CLOSING)
25
SIL Fault Signal "Actuator Monitoring": Check
26
Safe ESD Reaction for "Motor Protection (Thermal Fault)" Signals: Check
26
Safe ESD Reaction to "Limit Seating with Overload Protection
27
Safe ESD Reaction to "Forced Limit Seating in End Position" (Limit Evaluation) for Actu
29
Safe ESD Reaction for "Forced Limit Seating in End Position" (Limit Evaluation) for Actu
29
Safe ESD Reaction to "Forced Torque Seating in End Position
30
Safe ESD Reaction for "No Seating" (no Evaluation of Limit and Torque): Check
31
Safe STOP Function: Check
32
Combination of Safe ESD and Safe STOP Function: Check
33
Maintenance
34
Determination of the Figures
35
Safety-Related Figures
35
Specific Figures for AC 01.2 Controls in SIL Version with Actuators of SA.2 Series
36
SIL Certificate
39
Checklists
40
Commissioning Checklist
40
Proof Test Checklists
40
Safe ESD Safety Operation (Safe OPENING/CLOSING)
40
SIL Fault Signal "Actuator Monitoring
40
Safe ESD Reaction to "Motor Protection (Thermal Fault)" Signals
41
Safe ESD Reaction to "Limit Seating with Overload Protection
42
Safe ESD Reaction to "Forced Limit Seating in End Position" (Limit Evaluation) for Actu
42
Safe ESD Reaction to "Forced Torque Seating in End Position
44
Safe ESD Reaction to "No Seating
44
Safe STOP Function
45
11.2.10. Combination of Safe ESD and Safe STOP
46
Index
49
Addresses
50
Other manuals for AUMA SAR 07.2
Operation Manual
108 pages
Operating Instructions
104 pages
Operation Instructions
100 pages
Assembly Instructions
3 pages
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the AUMA SAR 07.2 and is the answer not in the manual?
Ask a question
AUMA SAR 07.2 Specifications
General
Type of actuator
Multi-turn actuator
Protection class
IP68
Output speed
4 to 180 rpm
Ambient temperature
-25°C to +70°C
Housing material
Aluminum
Related product manuals
AUMA SAR 07.6
104 pages
AUMA SAR 07.5
80 pages
AUMA SAR 07.1 - SAR 30.1
60 pages
AUMA SAR 6
44 pages
AUMA SAR 12
44 pages
AUMA SAR 10.2
104 pages
AUMA SAR 14.6
104 pages
AUMA SAR 14.1
80 pages
AUMA SAR 14.5
80 pages
AUMA SAR 10.1
80 pages
AUMA SAR 16.2
108 pages
AUMA SA 48.1 SAR 25.1
92 pages