Appendix
47 | P a g e
Wrap pot
voltage limit
hit- Power to
MP and LSP
motors cut.
1. System cuts power to MP motor and
LSP motor.
2. Throw Error
3. Lock Screen
This most likely occurs on while using
manual switches.
“S7 Overwind condition
See Supervisor ”
Notes: An S7 “Overwind Condition” error is typically caused by one using the manual switches and forcing the
machine to move in either the counter clockwise or clockwise position to its upper limits. If this occurs the
wind indicator lights will turn red on the control panel and power will be cut to the affected motor (MP or LSP).
If this occurs, the correct procedure is to center the platters manually using the manual switches. You must
move the platters until such time the wind indictor lights turn green. You can then turn the system off and have
it recalibrate in auto mode and continue.