ZoneLogix PRO Zone Controller User Guide | Revision 1.0 November 2019 | Page 29
7.2
Breakout Module Example: Connect Two Branches
This example shows a connection between two Branches. The Master on the left is connected to All Signals. This
refers to the fact that the RJ45 cable contains two communication systems; Branch Serial Communications (Master-to-
Zones) and Handshaking (Zone-to-Zone). The Breakout Module acts as a signal splitter. It takes theAll Signalsand
splits or ‘breaks outthe serial and Handshaking. In this example, the Breakout Module effectively connects the
Handshaking from the Master on the left Branch, to the Handshaking on the EOB on the right Branch. Therefore,
package flow can continue across Branches.
Figure 16: Breakout Module Connecting Two Branches
7.3
Breakout Module Example: Connect Two Branches with Branch Monitor
This example shows the same connection of two Branches as above, but also adds the connection to the Branch
Monitor. The Branch Monitor is used to configure the Branch on the left side. A separate Branch Monitor is required
for the Branch on the right.
Figure 17: Breakout Module Connecting Two Branches and Branch Monitor