9
4.6.6. Sensor settings
Menu Sensor Setting Possible settings Default setting
Cover/Ext command
Mode
Cover
OFF
Ext control
Cover
Type
NO
NC
NO
Flow/pH container
Mode
Flow
OFF
pH container
OFF
Type
NO
NC
NO
-
ON
OFF
ON
Temperature
Ext cmd: external command.
pH container: empty container sensor.
ON: sensor activated.
OFF: sensor disabled.
NO: switch normally open.
NC: switch normally closed.
Sensor activated Configuration
display
Production pH regulation
Cover
Cover open - Maintained
Maintained
Cover closed Divided by 5*
External command
Command activated - Maintained
Flow
Sufficient flow - Maintained
Zero flow
Stopped
Stopped
Empty container
Empty container
Maintained
Container not empty - Maintained
Maintained
Salt
Salt level less than 2.5 g/L
Stopped
Salt level equal to or greater than 2.5
g/L
- Sustained
Temperature
Water temperature below 15 °C
Stopped
Water temperature equal to or higher
than 15°C
- Sustained
* Value adjustable with the ORP option.