18
MESSAGE
DISPLAYED/FAULT
DETECTED
IMMEDIATE
AUTOMATIC ACTION
CAUSE
VERIFICATIONS AND
SOLUTIONS
OPTION TO
DEACTIVATE
VIA THE
MENU
Production
stopped
Stop of pH
regulation
Yes No
Salt level less than
2.5 g/L (or 1.5 g/L
if Low Salt
equipment).
Check the salt levels in the
pool using a recent testing
kit.
Top up with salt if
necessary, so as to
obtain
a salt level of 5 kg/m
3
(or
2.5 kg/m
3
for Low Salt
equipment).
Yes
Insufficient
amount of water
in the filtration
circuit.
Check that the tubing on
the salt sensor is
completely filled with
water.
If necessary, top up the
water in the pool.
4.7.4. Important precautions regarding the peristaltic pump
When one of the 2 messages below is displayed, the peristaltic pump is running.
-time timer countdown
or
I
In this case, do not remove the front panel of the electronics unit under any circumstances.
If case of doubt about the correct functioning of the peristaltic pump:
1) Switch off the electronics unit.
2) Remove the front panel of the electronics unit.
3) Remove the flexible tubing inside the peristaltic pump.
4) Carry out a manual vacuum injection.
4.8. Additional information
Menu Meaning
Control board programme
Power card programme
Configuration code
Serial number
MAC address for Bluetooth connection
Temperature inside the electronics unit