MESSAGE
DISPLAYED/FAULT
DETECTED
IMMEDIATE
AUTOMATIC ACTION
CAUSE CHECKS AND REMEDIES
OPTION TO
DISABLE VIA
THE
MENU
Stop of
production
Stop of pH
regulation
Yes Yes
Insufficient water
flow through the
filtration circuit.
Check that:
the flow sensor is
connected to the
electronic unit.
the flow sensor is
the filtration circuit valves
are open.
the filter pump is working
properly.
the filtration circuit is not
blocked.
there is enough water in
the pool.
No
Yes No
Loss of
communication
between the
control board and
the power board
of the electronics
unit.
Contact a professional. No
No No
pH probe
incorrectly
calibrated.
Calibrate the pH probe. Yes
No Yes
Series of 5
unsuccessful
attempts to
correct the pH.
Ensure the pH corrector
container is not empty.
Perform a manual
Check the condition of the
ballast filter and injection
connector.
Check the settings in the
and
menus.
Calibrate the pH probe.
Yes
Yes Yes
Insufficient
amount of water in
the filtration
circuit.
Check that the filtration
pump is working correctly.
Yes
Yes No
ORP measurement
beyond tolerance
for 48 hours 400
mV difference
compared to the
ORP setpoint).
Calibrate the ORP probe.
check that the production
setting is 100%.
Yes