EasyManua.ls Logo

Avady Propilot Salt - Safety Devices; Incorrect Measurement and Procedure to Increase the TAC; Overwintering Mode

Avady Propilot Salt
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
4.7. Safety devices
4.7.1. Incorrect measurement and procedure to increase the TAC
If the measurement displayed on the device is different to the value obtained by another control method (drops,
strip, photometer), check that the TAC (Total Alkalinity Content) > 100 mg/L.
Procedure to increase the TAC
Stop the pH and chlorine regulator.
Add the quantity needed to the swimming pool; this is specified on the TAC packaging. It is preferable to
increase the TAC to 250 mg/L in 50 mg/L increments.
Wait for 4 hours until it is completely dissolved.
Start the pH pump.
When the pH < 7.8, restart your chlorine disinfection system.
For a stable pH: 120 mg/L < TAC < 250 mg/L
If your pH is equal to or higher than 8, the PROpilot will not start the chlorinator.
In this case, wait for the PROpilot to add a pH- dose to the pool or add pH- by hand.
4.7.2. Overwintering mode
Overwintering mode:
- is activated by default.
- switches on automatically when the water temperature falls below 15°C.
When overwintering mode is on:
-
- Production is stopped.
- The pH regulation is maintained if it is activated.
To switch off overwintering mode: press OK.
To disable the overwintering mode: go to the
Overwintering the probe:
- When overwintering the probe, this must be removed from the installation and kept away from frost.
- Clean the end of the probe with the AYACSOLNET02 cleaning solution. This is to remove the deposits incrusted
during its use in the swimming pool water.
-
probe. This assembly must be protected from frost at ambient temperature.
It is important to know that it is the peristaltic tube that needs to be protected when overwintering your device. It is
therefore recommended that clean water be pumped through the peristaltic tube to rinse this out. When
tube.