Avant e5
35
.
Parking brake switch
Switch on the parking brake
whenever leaving the driver's
seat.
The loader is equipped with a
brake system that locks the rear
wheels. The parking brake is
activated when loader is switched
off or when hydraulic pressure is
otherwise lost due to a failure.
Parking brake can be released
only when the loader is running
and the auxiliary hydraulics pump
creates enough pressure for the
brakes to release.
CAUTION
Using the parking brake while
machine is moving may cause
locking of wheels and sudden stop.
Always engage the parking brake
after stopping the machine first.
The parking brake should be used
to stop the machine only in
emergency. Repeated use while
driving will damage the brakes.
Multi-function display
The multi-function display shows the following
information when the loader is in normal operating
mode:
Battery charge level
Operating hours (symbol with letter p visible)
During start-up the display will quickly cycle through
the following:
Total pump run time
Total time of how long key has been in position
ON
Total traction pump run time
In case the control system of the loader has detected
a fault in the control system of the loader, the display
will show a diagnostics fault code. For more
information about diagnostics codes, see page 86.
Electric 12 V outlet
When operating attachments with electric features,
the electric harness of the attachment can be
connected to the 12-volt outlet on the dashboard.
The standard type outlet is powered when ignition is
switched on. Maximum current: 10 A.
The total 12 v electricity output capacity of the loader
is limited. This available power shared between
lights, control system, and all additional accessories,
such as seat heater etc. High-current accessories
should not be connected to this electric socket. Keep
in mind that all additional electric equipment reduce
the battery run time. Switch off all unnecessary
equipment.
There is an electric socket for the attachment on the
multiconnector if the loader is equipped with the
optional attachment control switch pack. In this case
the electric plug of the attachment will be connected
simultaneously with its hydraulic hoses. In case there
is no electric plug on the multiconnector of the
attachment, use the separate electric harness to
connect to the regular 12 V outlet of the loader. You
can also contact your Avant dealer to fit an electric
plug to the attachment multiconnector.
Risk of fire and electric shock - Never connect
any device directly to the battery.
WARNING
The battery is able to produce high
electric current that can burn or
injure severely, and even cause
death. Short-circuit can cause the
battery to burn or explode. Never
connect any device directly to the
48 volt systems of the loader.