AXIS Q6032-E PTZ Dome Network Camera
Events
Events
The Axis p roduct can be configured to pe rform actions w he n different e vents occur, for example, star t a recording when motion is
detected. The set of conditions that defines how and when the action is triggered is c alled an Action Rule.
Available Action Rule triggers and conditions include:
• Applications — use installed applications to trigger the rule, see
Applications, on page 30
.
• Detectors
- Motion Detection — trigger the rule when motion is detected, see
Motion Detection, on page 28
.
• Hardware
- Open Casing Detection — trigger the rule if the casing of a connected external device, such as a junction
box or cabinet (not included), is removed or opened. This can for example be used to s end notifications of
maintenance or unauthorized tampering.
- Fan — trig ger the rule if the fan is m alfunctioning. Thiscanforexamplebeusedtosendmaintenance
notifications.
- Heater — tri gger the rule if the heater is malfunctioning. This can for example be used to send maintenance
notifications.
- Network — trigger the rule if network connection is lost or resto red. This can for example be used to start
recording to the SD card.
• Input Signal
- Manual Trigger — trigger t he rule using the Manual Trigger button in the Live View page, see
Controls on the
Live View Page, on page 8
. This can for example be used to validate actions d
uring product installation
and configuration.
• PTZ
- Autotracking — trigger the rule when autotracking starts or stops, see
Autotracking, on page 23
.
- Moving — trigger the rule when the camera view moves due to a PTZ operation. This can for example be used
as an additional condition to prevent an action rule triggered by motion detection to record video while the
camera view moves due to a PTZ op
eration.
- Preset Reached —trigger
therulewhenthecamerastopsatapresetposition.Thiscanbeforexamplebeused
with the Send Images action to upload images from the preset position.
• Storage
- Available — trigger the rule when the storage device is unmounted or removed. This can for example be
used to send maintenance notifications.
- Full — trigger the rule when the storage device is full. Under normal operation, the oldest recordings will b e
o
verwritten to pre ve nt the storage device from becoming full.
- Locked —triggertheruleifthestoragedeviceislocked(writeprotected).
• System
- System Initializing — trigger the rule when the product is being started. This can for examp le b e used to send a
notification when the product restarts.
• Time
31