AXIS Q6032-E PTZ Dome Network Camera
System Options
IEEE 802.1X
IEEE 802.1X is a standard for port-based Network Admission Control providing secure authentication of wired and wireless network
devices. IEEE 802.1X is based on EAP (Extensible Authentication P rotocol).
To access a network protected b y IEEE 802.1X, devices must authenticate themselves. The authentication is performed by a
third-party e ntity called an authentication server, typically a RADIUS server, examples of which are FreeRADIUS and Microsoft
Internet Authentication Service.
In Axis' implementation, the netwo rk de vice and the authe ntication server authenticate themselves with the help of digital
certicates using EAP-TLS (Extensible Authentication Protocol - Transport Layer Security). The certicates are provided by an
Certication Authority (CA). You need:
•aCAcerticate to validate the identity of the authentication server
a CA-signed client certicate and a private key to authenticate the network device.
To allow the network device to access a network protected by IEEE 802.1X:
1. Obtain a CA certicate, a client certicate and a client private key (contact your network administrator).
2. Go to Setup > System Options > Security > IEEE 802.1X and upload the CA certicate, the client certicate and the
client private key.
3. Under Settings, select the EAPOL version, provide your EAP identity and private key password.
4. Check the box to enable IEEE 802.1X and click Save.
Certicates
CA Certicate The CA certicate is used to validate the identity of the authentication server. Enter the path to
the certicate directly, or locate the le using the Browse button. Then click U
pload.Toremove
acerticate, click Remove.
Client certicate
Client private key
The client certicate and private key a re used to authenticate the network device. They can be
uploaded as separate les or in one combined le (e.g. a PFX le or a PEM le). Use the Client
private key eld i f uploading one combined le. For each le, enter the path to the le, or locate the
le using the Browse button. Then click Upload.Toremoveale, click Remove.
Settings
EAPOL version
SelecttheEAPOLversion(1or2)asusedinyournetworkswitch.
EAP identity
Enter the user identity (maximum 16 characters) a ssociated with your certicate.
Private key password
Enter the password (maximum
16 characters) for the private key.
Enable IEEE 802.1X
Check the box to enable the IEEE 802.1X protocol.
Date & Time
The Axis product’s date and time settings are congured under System Options > Date & Time.
Current Server Time displays the current date and time (24h clock). The time can be d isplayed in 12h clock in the text overlay (see
below).
To change the date and time settings, select the preferred Time mode under New Server Time:
Synchronize with computer time sets date and time according to the computer’s clock. With this option, date a nd
time are set once and will not be updated automatically.
Synchronize w ith NTP Server obtains date and time from an NTP server. With this option, date and time settings are
updated continuously. For informatio n on NTP settings, see
NTP C onguration, on page 40
.