1.3 Technical Data
Nominal Data
Nominal Voltage Vac
Three phase: 3x480Vac +10% max, 3x380Vac -10%, 50/60Hz
Three phase: 3x230Vac +10% max, 3x110Vac -10%, 50/60Hz
Single phase: 1x230Vac +10% max, 1x110Vac -10%, 50/60Hz
(SINGLE PHASE DOES NOT ALLOW TO OBTAIN THE RATED TORQUE AND
SPEED. CONTACT AXOR'S TECHNICAL DEPARTMENT FOR DETAILS.)
Mix/Max bus
voltage
Vdc
110Vac 230Vac 380Vac 480Vac
100Vdc min ÷ 415Vdc
max
220Vdc min ÷
415Vdc max
400Vdc min
÷ 800Vdc
max
500Vdc min ÷
870Vdc max
Auxiliary power
supply
(for back up)
Vdc +24Vdc (0%, +15%) - 1Adc (3Adc with brake)
Size
MM 400T MM 230T MM 220M
1,5/3 3,5/7 6/12 1,5/3 3,5/7 6/12 1,5/3 3,5/7 6/12
Nominal Current Arms
1,5 3,5 6 1,5 3,5 6 1,5 3,5 6
Peak current for
5 sec.
Arms
3 7 12 3 7 12 3 7 12
PWM output
frequency
kHz 8
Control signals
Optoisolated digital inputs +24Vdc - 7mA (PLC compatible)
Optoisolated digital outputs +24Vdc - 50mA (PLC compatible)
Analog programmable outputs ±10V (±5%)
Analog common mode input (TPRC) ±10V max, 20kOhm input resistance
Analog differential or common input
(+/-Vref)
±10V max, 40kOhm input resistance
Pulse/Dir digital inputs +5V, optoisolated, max. frequency 250kHz
Emulated encoder outputs
V
OH
=2.5V min - I
OH
=-20mA
V
OL
=0.5V max - I
OL
=20mA
Braking Resistance
Internal Resistance 100W - 66 ohm
External Resistance
500W - 66 ohm
1000W - 33 ohm + 33 ohm (500W)
Set point values
110Vac 230Vac 380Vac 480Vac
385Vdc min ÷
400Vdc max
385Vdc min ÷
400Vdc max
695Vdc min ÷
735Vdc max
815Vdc min ÷
845Vdc max
External Protections (fuses or similar)
Size
MiniMagnum 400T MiniMagnum 230T MiniMagnum 230M
1,5/3 3,5/7 6/12 1,5/3 3,5/7 6/12 1,5/3 3,5/7 6/12
Power supply
(F
2
)
4A /
500V
(TL)
6A /
500V
(TL)
10A /
500V
(TL)
3A /
250V
(TL)
5A /
250V
(TL)
8A /
250V
(TL)
3A /
250V
(TL)
5A /
250V
(TL)
8A /
250V
(TL)
Ext. brak.
resistor (F
4
)
4A F 6A F 4A F 6A F 4A F 6A F
Aux. pow.
supply (F
3
)
6A (Time Lag)