AXOR Industries Service Manual MiniMagnum
TM
ver.1 rev.05/'15
45
You can nd more information in enclosure "Alarm Manual" available in the CD provided with the
drive.
AL27
Encoder Pulse Counting Error
Incorrect counting of the encoder pulses in a me-
chanical revolution of the motor shaft.
Check the connection of the shields in the green ca-
ble.
AL31
Intervention of the "IMMEDIATE STOP"
function.
The drive has detected the possibility of a "Run-
away Motor"
It only generates, in Historical Alarm, the massage
"AL5" (ENCODER ALLARM).
AL32
Maximum speed exceeded
The speed value set in the drive was exceeded.
This will generate Historical Alarm "AL32". And seb-
sequentlyit will generate "AL31" which will initiate
the Immediate Stop Function.
3.2 Alarms