Chapter 4. Operation
Function
setup
Function Setting Description
Default setting
Notes
12
Low ow cuto
00
0
1
02
03
04
No low ow cuto
Below the minimum displayed
ow rate*
1 % FS
2.5 % FS
5 % FS
01 If the gas type is set to
08
(user
specied), the low ow cuto point
is the set value multiplied by the
CF
.
CF
is the gas conversion factor and
can be set in
P-08
in parameter
setup mode.
* The minimum display may vary
depending on the model.
P. 28
30
Station address
setting
00
0
1
to
GG
Communication disabled
Station address
00 Can be set only for models with
RS-485.
3
1
Transmission
speed selection
00
0
1
02
9600 bps
4800 bps
2400 bps
00 Can be set only for models with
RS-485.
32
Data format
00
0
1
8-bit data, even parity, 1 stop bit
8-bit data, no parity, 2 stop bits
00 Can be set only for models with
RS-485.
*1. Totalizer output pulse rates
Function
setup
Function Setting CMS9500 CMS0002/0005 CMS0020/0050 CMS0200/0500
04
Event output 2 (EV2)
05
06
07
10 mL/pulse
100 mL/pulse
1000 mL/pulse
1 L/pulse
10 L/pulse
100 L/pulse
10 L/pulse
100 L/pulse
1000 L/pulse
*2. Analog output scaling settings
Func-
tion
setup
Function Setting CMS9500 CMS0002 CMS0005 CMS0020 CMS0050 CMS0200 CMS0500
0G
Analog output
scaling
00
0
1
02
03
04
0 to 500
0 to 300
0 to 200
0 to 100
Desired
scaling
0 to 2
0 to 1
0 to 0.5
0 to 0.2
Desired
scaling
0 to 5
0 to 3
0 to 2
0 to 1
Desired
scaling
0 to 20
0 to 10
0 to 5
0 to 2
Desired
scaling
0 to 50
0 to 30
0 to 20
0 to 10
Desired
scaling
0 to 200
0 to 100
0 to 50
0 to 20
Desired
scaling
0 to 500
0 to 300
0 to 200
0 to 100
Desired
scaling
e unit for the CMS9500 is mL/min. For other models the unit is L/min.