This parameter can be used to influence the IO-Link communication speed. 
Calculated using the multiplier and the basic cycle time, the IO-Link cycle time can be 
increased. 
The basic cycle time can be adjusted via the scroll-down menu; the multiplier can be 
adjusted decimally from 0..63. 
The start byte of the process data can be defined with the data section offset.  For the 
max. input data length, the actual process data length of the IO-Link device is entered. 
These settings are only for the input data. 
The visible data window for the input data can now be adjusted via an IO-Link module with 
appropriate process data length. 
No validation: Validation deactivated, every device will be accepted. 
Compatibility: Manufacturer ID and device ID are compared to the module data. 
The IO-Link communication is only started if there is a match. Manufacturer ID and device 
ID are entered in decimal format. 
Identity: Manufacturer ID and device ID as well as the serial number are compared to the 
module data. The IO-Link communication is only started if there is a match. 
Manufacturer ID and device ID are entered in decimal format, the serial number is entered 
in ASCII code. 
Explanation of the possible settings in the properties of the IO-Link port.