www.balluff.com 15english
6
Calibration procedure (continued)
6.3.2 Adjusting
The detailed procedure for adjusting is
described on page17 ff.
The factory set null point and end point is replaced by a
new start point and end point and the associated output
values can be adjusted. The start and end values can be
adjusted as you like up to the limits.
Adjustment is possible from serial number
120615000xxxxx xx onwards.
Steps
Move magnet to the new start position.
Read new start point by pressing the buttons.
Set the new start value by pressing the buttons.
New null point
Before
After
Fig. 6-4: Adjust a new start value
Move magnet to the new end position.
Read new end point by pressing the buttons.
Set the new end value by pressing the buttons.
New end point
Before
After
Fig. 6-5: Adjust a new end value
6.3.3 Reset
Restoring the transducer to its factory settings.
The detailed procedure for the reset is
described on page19.
New start value
New end value
BTL7-A/C/E/G5 __ -M ____ -K(8)-SR32/SR115/___
Micropulse Transducer - Rod Style

Other manuals for Balluff BTL7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Balluff BTL7 Series and is the answer not in the manual?

Balluff BTL7 Series Specifications

General IconGeneral
Measurement PrincipleMagnetostrictive
ResolutionUp to 1 μm (depending on model)
Operating Temperature-40°C to +85°C
Protection ClassIP67
Housing MaterialAluminum
Output SignalAnalog
Supply Voltage10V to 30V DC

Related product manuals