B&C Electronics CL 7685
Operator’s Manual - Rev. C - 05/05
- 20
[MODE] to go to
----------------------------------
_
D1 |0.700 ppm Cl2 | Cl/ClO
2
/O
3
values
[CAL] to activate the Zero/Sensitivity calibration procedure
[MODE] to go to
----------------------------------
_
D2 |TEMP.: 22.0°CM| Temperature value
M: manual value
[CAL] to activate the Temperature calibration or the manual Temperature value
selection procedures
[MODE] to go to
----------------------------------
_
D3 |SA: 0.60 * F à L| Set-point A parameters display
0.60 :set-point value
à :set-point actual state
* : Alarm on set point A activated
F : selected action (F=PFM - W=PWM - O=on/off)
L : selected function low/high (L-H)
[CAL] to activate the programming sequences for set-point A value, hysteresis and
delay time
[MODE] to go to
----------------------------------
_
D4 |SB: 0.80 * O ì H| Set-point B parameters display
0.80 : set-point value
ì : set-point actual state
* : Alarm on set point B activated
O : selected action (F=PFM - W=PWM - O=on/off)
H : selected function (L-H)
[CAL] to activate the programming sequences for set-point B value, hysteresis and
delay time