Registers Definition
10109 Number of passthrough successes API message passing statistics
10110 Number of passthrough timeouts
10111 Number of passthrough errors
10112 Passthrough success streak
10113 Number of 43 buffer successes DX80 Gateway automatic messaging buffer statistics
10114 Number of 43 buffer timeouts
10115 Number of 43 buffer errors
10116 43 buffer success streak
11000 Read map success count Read/Write maps statistics
12000 Write map success count
13000 Read map timeout count
14000 Write map timeout count
15000 Read map error count
16000 Write map error count
17000 Read map success streak
18000 Write map success streak
19000 Read map is in default
7.3 Reset Codes
The reset codes are in virtual register 11015 and define the condition of the last restart operation.
Code Definition
0 Undefined
1 Unknown
2 General
3 Brownout
4 Watchdog
5 User
6 Software
7 Return from backup mode
DXM100 Controller Instruction Manual