The OEM engine manufacturer species the
oil be MIL-L_2104C or have properties of API
classication CF or higher. Change the type of
engine oil according to the ambient temperature.
Above 77° F (25° C) 10W-30 or 10W-40 or
15W-40
14° F to 77° F
(-10° C to 25° C)
10W-30 or 10W-40 or
15W-40
Below 14° F (-10° C) 10W-30 or 10W-40
When using oil of different brands from the
previous one, be sure to drain all the previous
oil before adding the new engine oil. Refer to the
OEM engine manual for detailed oil information
and recommendations.
8. Slowly pour oil into the valve cover to raise oil
level to the F (full) mark.
NOTICE
Prevent engine damage.
Do not overll crankcase.
B
C
9. Replace ller cap and dipstick.
10. Close hydraulic cooler and tighten knobs (A).
Check Hydraulic Fluid Level
Check hydraulic uid level before the engine is rst
started and every 10 hours. AW32 is recommended
for general conditions and climates. MV22 is
recommended for colder climates.
Attachments can raise or lower the hydraulic uid
level. If a new attachment is connected, hydraulic
uid needed to ll the lines, cylinders or motor will
lower the hydraulic tank uid level. Check uid level
each time a different attachment is connected.
1. Skidsteer must be parked on a level surface,
lift arms fully lowered, engine stopped and key
removed.
A
B
2. Check uid level in sight glass (A). Hydraulic
uid should ll approximately 50% of the sight
glass. If the level is low, add enough uid to
raise it to the proper level.
3. Clean the area around the ller neck of the
hydraulic tank.
4. Remove the cap (B) from ller neck and add
hydraulic uid as needed.
5. Install the cap (B) on ller neck.