EasyManua.ls Logo

Baumuller BUS 6 VC - Page 64

Baumuller BUS 6 VC
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
62 V-Controller (BUS 6 VC)
5.03047.01 Baumüller Nürnberg Electronic GmbH & Co. KG
Parameter description
P190 DSM command
This command instructs the data set management to load, to save and to delete an existing
data set.
P191 DSM state
P192 DSM message
If a message occurs during the implementation of a command, it is displayed in this parame-
ter.
NOTE
This parameter is independent of the parameter M communication source (P126) always
changeable.
Command Meaning
0 reset of data set management
The parameter P191 till P195 are set automatically to 0.
5 save data set from user memory to EEPROM
6 load data set from EEPROM to user memory
7 delete EEPROM data set
8 input password
Bit no. Meaning
0 ... 2 000 : STOP Data set management is ready for a command or for changing data
sets.
001 : RUN Data set management is processing a command.
011 : STAND_BY Data set management has finished a command.
3 1 : An error has occurred in the data set management.
Error code see P124, M error code and P192, DSM message
4 ... 15 reserved
Bit no. Meaning
0 1: undefined command
1 1: data set not available
2 1: wrong check sum
3 1: parameter not changeable
4 reserved
5 1: memory full
6 1: error in configuration list
7 1: undefined parameter format

Related product manuals