EasyManua.ls Logo

Baumuller BUS 6 VC - Page 84

Baumuller BUS 6 VC
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
82 V-Controller (BUS 6 VC)
5.03047.01 Baumüller Nürnberg Electronic GmbH & Co. KG
Parameter overview
Parameter description
P382 DI state
This parameter indicates the state of input programming.
parameter Name Range
min. ... max.
Unit Display
only
P382 DI state 0000 ... FFFF
!
P370 DI 1 target Pxxx 0 ... 700
P371 DI 1 bit selection 0000 ... FFFF
P372 DI 1 LOW pattern 0000 ... FFFF
P373 DI 1 HIGH pattern 0000 ... FFFF
P374 DI 2 target Pxxx 0 ... 700
P375 DI 2 bit selection 0000 ... FFFF
P376 DI 2 LOW pattern 0000 ... FFFF
P377 DI 2 HIGH pattern 0000 ... FFFF
P378 DI 3 target Pxxx 0 ... 700
P379 DI 3 bit selection 0000 ... FFFF
P380 DI 3 LOW pattern 0000 ... FFFF
P381 DI 3 HIGH pattern 0000 ... FFFF
P342 DI 4 target Pxxx 0 ... 700
P343 DI 4 bit selection 0000 ... FFFF
P344 DI 4 LOW pattern 0000 ... FFFF
P345 DI 4 HIGH pattern 0000 ... FFFF
Bit no. Meaning
0 1: input 1 completely programmed
1 1: input 2 completely programmed
2 1: input 3 completely programmed
3 1: input 4 completely programmed
4 ... 7 reserved
8 actual state input 1 (X26:15)
9 actual state input 2 (X26:16)
10 actual state input 3 (X26:17)
11 actual state input 4 (X26:18)
12 ... 13 reserved
14 actual state rapid halt input (X26:19)
15 actual state pulse / controller enabling (X26:14)