7219623.01 (1-04/15) 36
INSTALLER Section (en)
14. PARAMETERS SETTING
Press and P01” appears on the display alternated
Press
Press
Press
Further information concerning the parameters listed in the following table are supplied together with the required
accessories.
DESCRIPTION OF PARAMETERS FACTORY SETTINGS
P01 Manufacturer information 00
P02
Gas used
00 01
00
P03 Hydraulic system 01
P04
Programmable relay 1 settings (See SERVICE instructions)
00
01
02
03
04
05
06-07
08
09
programming from remote control
10
11 - 12 - 13
02
P05
Programmable relay 2 settings (See SERVICE instructions)
04
P06
(See SERVICE Instructions)
00
P07..P09 Manufacturer information --
P10
Heating setpoint setting OT / RT
(Remote Control - Open Therm / Room Thermostat 230V~)
00
01
and PCB
02
Thermostat enable the gas boiler operates
03
Remote Control):
a)PCB (Ambient Thermostat): the setpoint is set by pressing the +/-
Remote Control from the boiler.
b)Remote Control: the setpoint is set by modifying the “ULt” parameter
(see Room Unit accessory manual, chapter “INSTALLER FUNCTIONS”)
c)Simultaneous request PCB - Remote Control the higher setpoint of the
00
P11..P12 Manufacturer information --
P13 Max. heating output (0-100%) 80
P14 DHW max. output (0-100%) 100
P15 Min. heating output (0-100%) 00
P16
00 01
00
P17 Pump overrun time in heating mode (01-240 minutes) 03
P18 Burner ignition delay in CH mode (00-10 minutes) - 00=10 seconds 03
P19 Manufacturer information 07
P20 Pump overrun time in DHW mode (seconds) 30