CALDAIA MURALE A GAS A CONDENSAZIONE
Manuale per l’uso destinato all’utente e all’installatore
en CONDENSING GAS WALL-HUNG BOILERS
Instructions manual for users and tters
cs PLYNOVÉ ZÁVĚSNÉ KONDENZAČNÍ KOTLE
Návod na použití pro uživatele a instalatéry
sk PLYNOVÉ ZÁVESNÉ KONDENZAČNÉ KOTLE
Návod na použitie pre užívateľov a inštalatérov

Table of Contents

Questions and Answers

  • B
    Brian HarrisSep 23, 2025
    How to fix internal board error on Baxi DUO-TEC MAX+ Boiler?
    • R
      Roberto HobbsSep 23, 2025
      If your Baxi Boiler has an internal board error, replace the electronic board.
  • K
    Kurt ShortAug 23, 2025
    What to do if pressure is too low in Baxi DUO-TEC MAX+?
    • M
      Michael SteinAug 23, 2025
      If the pressure in the hydraulic circuit of your Baxi Boiler is too low, and the pressure in the CH circuit is less than 0.5 bar, perform filling. Also, check that the hydraulic pressure switch works correctly.
  • E
    Eric HernandezAug 25, 2025
    How to fix no flame on Baxi Boiler?
    • A
      Andrew KruegerAug 26, 2025
      If your Baxi Boiler is not igniting ('no flame' error), check that the flame sensing electrode is in good condition and correctly positioned. Also, check the wire is uninterrupted and makes good contact with the flame sensing electrode and the ignition switch.
  • B
    Brittany ClarkAug 27, 2025
    Why is flame lost at ignition in Baxi Boiler?
    • H
      hmaysAug 27, 2025
      If you're experiencing a loss of flame at ignition with your Baxi Boiler, check that the flame sensing electrode is in good condition and correctly positioned. Also, check the wire is uninterrupted and makes good contact with the flame sensing electrode and the ignition switch. Check for any recirculation of fumes.
  • S
    Sarah AbbottAug 27, 2025
    What to do if the safety thermostat tripped due to overtemperature in Baxi DUO-TEC MAX+ Boiler?
    • T
      Tamara CantuAug 28, 2025
      If the safety thermostat in your Baxi Boiler trips due to overtemperature, which might be caused by a blocked pump or air in the heating circuit, you should check the pump operation by unscrewing the front cap and releasing the pump impeller with a screwdriver. Also, check the pump power input wiring. Inspect the limit thermostat for damage and replace it if necessary, and verify the continuity of the limit thermostat wiring.
  • A
    Amy BurchSep 17, 2025
    How to troubleshoot NTC flow sensor faulty on Baxi Boiler?
    • S
      shumphreySep 18, 2025
      If the NTC flow sensor is faulty on your Baxi Boiler, check the sensor, the continuity of the probe wiring, and make sure the wiring has not shorted.
  • S
    Steven ScottSep 14, 2025
    How to fix parasite flame (internal error) in Baxi DUO-TEC MAX+ Boiler?
    • J
      Jill BaileySep 14, 2025
      If your Baxi Boiler displays 'Parasite flame (internal error)', check correct operation of the gas valve.
  • A
    Adrian FosterSep 15, 2025
    How to troubleshoot external probe sensor faulty on Baxi Boiler?
    • N
      Nicholas ParsonsSep 16, 2025
      To address a faulty external probe sensor on your Baxi Boiler, check the sensor.
  • S
    Stephen HicksSep 6, 2025
    What to do if Baxi DUO-TEC MAX+ Boiler shows incorrect power supply frequency?
    • R
      Ryan WilsonSep 6, 2025
      If your Baxi Boiler displays 'Incorrect power supply frequency', check whether the incorrect electric power supply frequency is due to causes outside the boiler; if so, contact the power supply company.
  • N
    Nicole WallaceSep 3, 2025
    How to troubleshoot gas valve connection error on Baxi DUO-TEC MAX+?
    • M
      mwaltersSep 3, 2025
      If your Baxi Boiler displays a gas valve connection error, check the connections between the gas valve and the electronic board.

Summary

Description of Symbols

Safety Warnings

Provides critical safety instructions regarding gas, fumes, and flammable materials.

General Precautions

Energy-Saving Tips

Offers advice on optimizing boiler performance and reducing energy consumption through temperature settings.

Commissioning the Boiler

Adjusting CH and DHW Flow Temperature

Explains how to set the desired flow temperatures for central heating (CH) and domestic hot water (DHW).

Operating Modes

Describes the different operating modes available for the boiler, such as DHW only or heating only.

Prolonged Shutdown. Anti-Freeze Protection

Gas Conversion

Faults

Boiler Information Menu

Switching Off the Boiler

Filling the System

Routine Maintenance Instructions

Instructions Prior to Installation

Contents of Pack

Lists the items included in the boiler's packaging.

Boiler Dimensions and Gas Water Connections

Provides technical drawings and specifications for boiler dimensions and connection points.

Installing the Boiler

Installing the Flue

Concentric Ducts

Details the installation of concentric flue ducts, including length limitations and bending rules.

Separate Ducts

Describes the installation of separate flue and air ducts using an accessory splitting kit.

Electrical Connections

Connecting the Room Thermostat

Guides on how to connect a room thermostat to the boiler's terminal block.

Accessories Not Included in the Supply

Introduces optional accessories that can be connected, such as external sensors and zone systems.

Special Functions

Initial Ignition

Provides a detailed procedure for the first-time ignition and gas recognition process of the boiler.

System Gas Extraction Function

Describes the function used to remove air from the heating circuit after installation or maintenance.

Chimney Sweeper

Explains how to activate the chimney sweep function for maximum heating power adjustment.

Combustion Test (CO₂%)

Details how to perform combustion tests and check CO₂ levels for optimal boiler operation.

Pre-Heat Function

Explains the pre-heat function that improves hot water comfort by providing instant hot water.

Gas Valve

Gas Conversion Methods

Outlines the process for converting the boiler from natural gas to LPG and vice-versa by an authorized service.

Parameters Setting

Adjusting Maximum Heating Power

Details how to adjust the maximum heating power using parameter P13 to match system requirements.

Troubleshooting Service Faults

Adjustment and Safety Devices

Pump Capacity;Head

Annual Servicing

Hydraulic Unit

Focuses on the hydraulic unit, including water treatment advice and filter cleaning.

Positioning the Electrodes

Provides specific instructions and diagrams for correctly positioning the ignition and flame sensing electrodes.

Replacement of Parts

Lists components that require performing the automatic calibration procedure after replacement.

Dismantling, Disposal and Recycling

Technical Specifications

Technical Parameters

Product Fiche

Baxi DUO-TEC MAX+ Specifications

General IconGeneral
TypeCombi
MountingWall-mounted
ErP HeatingA
ErP WaterA
NOx Class5
Output Range24kW
Weight36.5 kg
Fuel TypeNatural Gas
Hot Water Flow Rate16.4 l/min