Baxi DUO-TEC MAX+ - User Manual

Baxi DUO-TEC MAX+
104 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
it
CALDAIA MURALE A GAS A CONDENSAZIONE
Manuale per l’uso destinato all’utente e all’installatore
en CONDENSING GAS WALL-HUNG BOILERS
Instructions manual for users and tters
cs PLYNOVÉ ZÁVĚSNÉ KONDENZAČNÍ KOTLE
Návod na použití pro uživatele a instalatéry
sk PLYNOVÉ ZÁVESNÉ KONDENZAČNÉ KOTLE
Návod na použitie pre užívateľov a inštalatérov

Table of Contents

Questions and Answers

  • N
    Nicholas ButlerSep 7, 2025
    What to do if Baxi Boiler shows input voltage too low?
    • L
      Lauren WalshSep 7, 2025
      If your Baxi Boiler displays 'Input voltage too low', and the input voltage is less than 175V, check whether the power supply reductions are due to reasons other than the boiler. If so, contact the electricity provider.
  • T
    tony04Aug 22, 2025
    What to do if Baxi DUO-TEC MAX+ Boiler has ignition failure (5 attempts)?
    • A
      Ariana BennettAug 22, 2025
      If your Baxi Boiler experiences an ignition failure after 5 attempts, ensure the gas valve is open and there's no air in the gas supply. Verify the gas supply pressure and check that the wire is uninterrupted and makes good contact with the flame sensing electrode and the ignition switch. You may also need to check the correct operation of the condensate drainage.
  • C
    Christopher AndrewsSep 5, 2025
    How to fix fumes outlet obstructed on Baxi DUO-TEC MAX+?
    • E
      Edwin DuranSep 5, 2025
      If your Baxi Boiler's fumes outlet is obstructed, check that the drainage pipe is free from obstructions and switch off the electric power supply to the boiler for a few seconds.
  • N
    Nicole WallaceSep 3, 2025
    How to troubleshoot gas valve connection error on Baxi DUO-TEC MAX+?
    • M
      mwaltersSep 3, 2025
      If your Baxi Boiler displays a gas valve connection error, check the connections between the gas valve and the electronic board.
  • C
    Christina DunnSep 2, 2025
    How to troubleshoot gas valve control error on Baxi Boiler?
    • E
      Eric EvansSep 2, 2025
      If your Baxi Boiler displays a gas valve control error, check the connections between the gas valve and the electronic board. If necessary, replace the electronic board.
  • S
    Stephanie BenitezAug 31, 2025
    How to troubleshoot gas valve blocked error in Baxi DUO-TEC MAX+ Boiler?
    • D
      Douglas JohnsonAug 31, 2025
      If your Baxi Boiler shows a gas valve blocked error, check the gas supply pressure and inspect the integrity and position of the sensing and ignition electrodes and their wiring. If necessary, replace the electronic board.
  • H
    hguerreroAug 30, 2025
    What causes fumes NTC to trip in Baxi Boiler?
    • R
      Robin AguilarAug 30, 2025
      If the fumes NTC in your Baxi Boiler tripped due to overtemperature, check the heat exchange level of the water-fumes exchanger for insufficient circulation or scale presence. Also, check the fumes NTC probe.
  • B
    Brittany DrakeAug 29, 2025
    How to fix fan fault in Baxi DUO-TEC MAX+?
    • K
      Kyle RodriguezAug 29, 2025
      If your Baxi Boiler displays a 'Fan fault', check the correct operation of the fan and ensure that the fan power supply wiring is connected to the electronic board.
  • S
    Sarah AbbottAug 27, 2025
    What to do if the safety thermostat tripped due to overtemperature in Baxi DUO-TEC MAX+ Boiler?
    • T
      Tamara CantuAug 28, 2025
      If the safety thermostat in your Baxi Boiler trips due to overtemperature, which might be caused by a blocked pump or air in the heating circuit, you should check the pump operation by unscrewing the front cap and releasing the pump impeller with a screwdriver. Also, check the pump power input wiring. Inspect the limit thermostat for damage and replace it if necessary, and verify the continuity of the limit thermostat wiring.
  • B
    Brittany ClarkAug 27, 2025
    Why is flame lost at ignition in Baxi Boiler?
    • H
      hmaysAug 27, 2025
      If you're experiencing a loss of flame at ignition with your Baxi Boiler, check that the flame sensing electrode is in good condition and correctly positioned. Also, check the wire is uninterrupted and makes good contact with the flame sensing electrode and the ignition switch. Check for any recirculation of fumes.

Summary

Description of Symbols

Safety Warnings

Provides critical safety instructions regarding gas, fumes, and flammable materials.

General Precautions

Energy-Saving Tips

Offers advice on optimizing boiler performance and reducing energy consumption through temperature settings.

Commissioning the Boiler

Adjusting CH and DHW Flow Temperature

Explains how to set the desired flow temperatures for central heating (CH) and domestic hot water (DHW).

Operating Modes

Describes the different operating modes available for the boiler, such as DHW only or heating only.

Prolonged Shutdown. Anti-Freeze Protection

Gas Conversion

Faults

Boiler Information Menu

Switching Off the Boiler

Filling the System

Routine Maintenance Instructions

Instructions Prior to Installation

Contents of Pack

Lists the items included in the boiler's packaging.

Boiler Dimensions and Gas Water Connections

Provides technical drawings and specifications for boiler dimensions and connection points.

Installing the Boiler

Installing the Flue

Concentric Ducts

Details the installation of concentric flue ducts, including length limitations and bending rules.

Separate Ducts

Describes the installation of separate flue and air ducts using an accessory splitting kit.

Electrical Connections

Connecting the Room Thermostat

Guides on how to connect a room thermostat to the boiler's terminal block.

Accessories Not Included in the Supply

Introduces optional accessories that can be connected, such as external sensors and zone systems.

Special Functions

Initial Ignition

Provides a detailed procedure for the first-time ignition and gas recognition process of the boiler.

System Gas Extraction Function

Describes the function used to remove air from the heating circuit after installation or maintenance.

Chimney Sweeper

Explains how to activate the chimney sweep function for maximum heating power adjustment.

Combustion Test (CO₂%)

Details how to perform combustion tests and check CO₂ levels for optimal boiler operation.

Pre-Heat Function

Explains the pre-heat function that improves hot water comfort by providing instant hot water.

Gas Valve

Gas Conversion Methods

Outlines the process for converting the boiler from natural gas to LPG and vice-versa by an authorized service.

Parameters Setting

Adjusting Maximum Heating Power

Details how to adjust the maximum heating power using parameter P13 to match system requirements.

Troubleshooting Service Faults

Adjustment and Safety Devices

Pump Capacity;Head

Annual Servicing

Hydraulic Unit

Focuses on the hydraulic unit, including water treatment advice and filter cleaning.

Positioning the Electrodes

Provides specific instructions and diagrams for correctly positioning the ignition and flame sensing electrodes.

Replacement of Parts

Lists components that require performing the automatic calibration procedure after replacement.

Dismantling, Disposal and Recycling

Technical Specifications

Technical Parameters

Product Fiche

Baxi DUO-TEC MAX+ Specifications

General IconGeneral
TypeCombi
MountingWall-mounted
ErP HeatingA
ErP WaterA
NOx Class5
Output Range24kW
Weight36.5 kg
Fuel TypeNatural Gas
Hot Water Flow Rate16.4 l/min