TX1500 Manual V3.5 Dec 07 Page 24 of 40 MATRIX PROGRAMMING/USER GUIDE
SYSTEM PARAMETERS
Used to program additional settings as follows:
System Parameters 2:
Displays the 2
nd
page of system parameters.
Menu Timeout:
Number of seconds of inactivity before the menu is automatically exited. Use +/- to cycle through values.
15, 20, 40, 60, 80, 100, 120, 150, 180, 200 or 250 seconds.
Program Timeout:
Number of seconds the keyboard will stay in programming mode after the PROGRAM key is pressed. This is to prevent
preset positions from being overwritten accidentally. Use +/- to cycle through values.
15, 20, 40, 60, 80, 100, 120, 150, 180, 200 or 250 seconds. It is recommended that a short time is selected.
Lockout Delay:
Number of seconds that the PTZ control of a camera is locked out after the last movement command. Used to prevent
two keyboards from ‘fighting’ for control of the same camera. Use +/- to cycle through values.
3, 5, 8, 10, 12, 15, 20, 30, 40, 60, 80, 100 or 250 seconds. 10 seconds would be an appropriate value.
Relay 0 Action:
Latching – Pressing the keyboard’s TRIANGLE key will toggle the state of the monitor output card relay.
Momentary – The relay will switch whilst the TRIANGLE key is pressed and switch back again when the key
is released.
System Parameters
System Parameters 2
Menu Timeout 60 Seconds
Program Timeout 20 Seconds
Lockout Delay 10 Seconds
Relay 0 Action Latching
Return