User Manual 14
Proper area to install the printer
In order to ensure easy access to the printer during normal operations and maintenance, install the machine in a
place with enough space between walls and other equipment.
The distance measured from the back of the printer to the wall has to be at least 200mm to allow easy access from
the side of the printer. This space is important to guarantee easy access to extruders, FRS and external spools.
Do not cover the printer while working in order to ensure a good ventilation. Do leave at least 100mm of free space
on each side of the printer for proper ventilation and at least 600mm at the front of the printer to open the door.
Install the printer on a table or workbench that supports at least 50kg (recommended 100kg) and that has at least
a 20% more surface than the footprint of the printer in each direction (recommended 1000mm x 800mm).
Use the machine at temperatures of 15 °C ~ 30 °C and relative humidity below 50%.