EasyManua.ls Logo

BEA IS40 - Remote Control Parameters; Motion Detection Settings; Rejection Mode Configuration; Output Configuration

BEA IS40
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 6 of 8 75.5695.08 IS40 IS40XL 20230627
XXS
0.5 s
XS
1 s
1
bi
S
2 s
2
uni
>
3 s
3
uni
AWAY
>
4 s
4
>
5 s
5
bi = two-way detection
uni = one-way detection towards sensor
uni AWAY = one-way detection away from sensor
>
6 s
6
L
7 s
XL
8 s
XXL
9 s
Mounting Height Width* Depth*
8 ft 5 ft 5 ft
10 ft 7 ft 7 ft
11.5 f t 7.5 f t 7.5 f t
13 ft 8.5 ft 8.5 ft
16 ft 10 ft 10 ft
MAXIMUM Mounting Height
IS40XL 11.5 f t
IS40 16 ft
OUTPUT
CONFIGURATION
DOOR EXAMPLE
First Line
Last Line
PRESENCE RELAY IS40 / IS40XL
LED
0 – 6: ALL MODES Activates when object is in presence zone.
red
ACTIVATION RELAY IS40 / IS40XL
LED
0: STANDARD MODE Activates when motion detected.
green
1: PULSE ON ENTRY
Activates if object motion is detected and then
object enters presence zone.
2: PULSE ON EXIT
Activates if object motion is detected and then
object exits presence zone.
3: PULSE ON ENTRY FIRST / LAST LINE
see example (left)
Activates if object motion is detected and then
object enters presence zone (first or last line).
4: PULSE ON EXIT FIRST / LAST LINE
see example (left)
Activates if object motion is detected and then
object exits presence zone (first or last line).
5: REMAINS ACTIVE UNTIL PRESENCE ZONE
IS CLEARED (regardless of motion)
Activates when motion is detected and remains
active until the presence zone is cleared.
6: REMAINS ACTIVE UNTIL PRESENCE ZONE
IS CLEARED (regardless of motion)
Activates when motion is detected and AIR is
detected and remains active until the presence
zone is cleared.
FIELD SIZE
(SENSITIVITY)
DETECTION MODE
DETECTION FILTER
(REJECTION MODE)
3 Low ‘Pedestrian/Parallel traffic’ Rejection + Interference Immunity
4 Medium ‘Pedestrian/Parallel traffic’ Rejection + Interference Immunity
5 High ‘Pedestrian/Parallel traffic’ Rejection + Interference Immunity
6 Extra High ‘Pedestrian/Parallel traffic’ Rejection + Interference Immunity
1 Detection of all Targets in Motion
2 Detection of all Targets in Motion + Interference Immunity
Detection of ALL TARGETS
(pedestrians, vehicles and parallel traffic are detected)
Detection only of VEHICLES MOVING TOWARDS THE SENSOR
(pedestrians and parallel traffic are not detected + immunity filter)
AIR PATTERN SIZE AT 15
O
SENSOR ANGLE
mounting height increases AIR pattern increases
* Dimensions are approximate.
HOLD-OPEN TIME
POSSIBLE REMOTE CONTROL SETTINGS
(motion sensing)

Other manuals for BEA IS40