OVERVIEW OF SETTINGS
MENU
ConfiLCD
DISPLAY
PARAMETERS DESCRIPTION
Menu 1 (BASIC)
DoorType
Undefined
Single
Pair
DualEgr
InDualEgr
Type of door system on which sensors are installed:
Single: Single Door Pair: Pair of Doors
DualEgr: Dual-egress Doors InDualEgr: Independent Dual-egress Doors
DetectZoneA
1
20 – 48 Distance (in inches) from sensor LED to leading edge of Door A [round down]
DetectZoneB
1
20 – 48 Distance (in inches) from sensor LED to leading edge of Door B [round down]
Guiderail 0 – 60 Guiderail height from floor (in inches)
Menu 2 (ADVANCED)
Monitoring
2
Off
Safe
Stall
Safe&Stall
Act
Act&Stall
Type of monitoring:
Off: No Monitoring Safe: Monitoring of Safety Signal
Stall: Monitoring of Stall Signal Safe&Stall: Monitoring of Safety & Stall Signals
Act: Monitoring of Activation Signal Act&Stall: Monitoring of Activation & Stall Signals
KnowingAct Off On Turns Knowing Act Off or On
Act:HoldTime 1 - 5 - 30 Time activation relay will be held after loss of detection (in seconds)
PushNGo Off On Turns Push-And-Go Off or On
NotCloseTime 5 - 10 - 30 Time required for door to reach “Closed” from “Open” or “Manual” before switching to “NotClosed” (in seconds)
AdvanceSafe Off On
Type of safety provided while door(s) is/are currently open due to manual operation (or stack pressure):
Off: Allows door(s) to activate, via motion sensor or push plate
On: Prevents door(s) from activating, via motion sensor or push plate
Act:Dist
3
12 - 24 - 48 Door closed detection distance of Approach Sensor(s) (in inches)
MonitorLogic
2
ActiveLow
ActiveHigh
ActiveLow: 0V requests monitoring
ActiveHigh: > 0V requests monitoring
Safe:Dist
3
Deep
Medium
Limited
Door closed detection distance of Safety Sensor(s):
Deep: 4 curtains Medium: 3 curtains Limited: 2 curtains
Traffic
Normal
High
Extreme
When doors do not come closed for a certain period of time due to traffic flow
Normal: ≤ 5 min High: ≤ 30 min Extreme: > 30 min
Default parameters are in BOLD. Menu 1 (Basic) items MUST be programmed.
NOTES:
1. Detection zone “A” and “B” are the sensor pattern width and are determined by measuring the distance from the sensor LED to the leading edge of the door.
2. The sensor LED will briefly flash RED during monitoring communication with door control. This indicates that external monitoring is functional. Monitoring functionality must be active on the sensor
and monitoring wires must be properly connected to the door control.
3. The Approach Side Detection Zone (Act:Dist) and Swing Side Safety Zone (Safe:Dist) are independently adjustable.