8-12
Parameter
Explanation Settings
Factory
Setting
Customer
Pr.149
Gear Ratio for
Simple Index
Function
4 to 1000
200
Pr.150
Index Angle for
Simple Index
Function
00.0 to 360.0
180.0
Pr.151
Deceleration Time
for Simple Index
Function
0.00 to 100.00 sec
0.00
Pr.152
Skip Frequency
Width
0.00 to 400.0Hz
0.00
Pr.153
Bias Frequency
Width
0.00 to 400.0Hz
0.00
Pr.154 Reserved
a
Pr.155
Compensation
Coefficient for Motor
Instability
0.0: Disable
0.1 to 5.0 (recommended setting d2.0)
0.0
a
Pr.156
Communication
Response Delay
Time
0 to 200 (x500us)
0
a
Pr.157
Communication
Mode Selection
0: Delta ASCII
1: Modbus
1