GB Sound speed controller SFR-1
72 BEIER-Electronic 06.02.2019
The ship light functions can be configured to detect automatically the condition of "in
operation" or "at anchor" using the throttle channel #1. The condition "in operation" is
automatically switched off, if the throttle channel is in neutral for a defined time. After
the time has expired (1-255s), it will be switched for example from "in operation" to
"at anchor".
The smoke generator can be activated automatically with the engine sound 1 or
engine sound 2. If this option is not used, the smoke generator needs to be switched
on/off separately with the function “smoke generator on”.
For the output type “smoke generator fan” a trailing between 0 and 255 seconds can
be set. This helps to keep the hose free of condensation.
Configuration - Outputs - Light switch
With the light switch various lights can be controlled with the function "light switch +"
and "light switch -".
The light switch has in total 11 steps, which can be individually programmed. The
steps are divided in 6 positive and 4 negative steps. The number of steps that should
be used, can be selected as well as the active lights in each step. An active output is
indicated with a "" in the table.
For "reversing light possible", "brake light possible" and "indicator light
possible" a „“ does not mean that the lights are always switched on. Only when
the corresponding function is triggered, the lights will be activated.
In the standard setting for step -1 to -4 (blackout lighting for military vehicles)
reversing, brake and indicator lights are for example completely switched off.
All other lights are actually switched on if there is a „“ at the step.