2-28
Select the function and press the ENT-key. The main clamp moves back and
forth with high speed and must change direction at the same position.
5.5.2.4 Mitre knife motor
1. Press the P-key.
2. Press the F6-key.
3. Press the F3-key.
4. Press the F4-key.
Here two test functions are contained:
F1 Select mitre knife motor
ATTENTION
This function may only be executed by service technicians of the company
Beisler or authorized and especially trained staff.
F2 Mitre knife motor long-term test
Before execution, the movable mitre knife must be moved into starting
position (on intitiator 20).
Select the function and press the ENT-key. The mitre knife moves back and
forth with constant speed and must change direction always at the same
position.
Turn the mains/emergency stop switch to terminate the function.
5.5.2.5 Center knife motor
1. Press the P-key.
2. Press the F6-key.
3. Press the F3-key.
4. Press the F5-key.
Enter a value between 01 ... 99 to check the speed of the center knife motor.
Press the ENT-key to switch off the motor again.
If the center knife shall be switched on additionally, press the 0-key (zero).
You can also stop the center knife by pressing the ENT-key.
Press the P-key to terminate this function.
5.5.2.6 Final roller
1. Press the P-key.
2. Press the F6-key.
3. Press the F3-key.
4. Press the F6-key.
Enter a value between 01 ... 99 to check the speed of the final roller. Press
the ENT-key to switch off the motor again.
Press the P-key to terminate this function.
5.5.3 Service Code
Here two codes are contained, whith which all or only a part of the machine
data can be locked.