CHAPTER 15. 4 000 HOURS SERVICE
Introduction
The 4 000 hours service must be performed when
the machine has operated for 4 000 hours and the
service must be repeated every 4 000 hours thereaf-
ter.
Every 4 000 hours service must be performed by
qualified service personnel.
Service Instructions
Ensure that the machine is in the service position.
Refer to Pre-service Instructions, Chapter 7.
Perform all the Daily or 10 Hourly Service Checks.
Perform the following additional tasks:
Engine
Note: For further engine information or details not
shown in this manual, refer to the ADE Engine
Manuals OM 442 LA.
Change the Crankcase Breather (Oil
Separator)
1. Loosen the hose clamp (1) and pull the rubber
pipe (2) from the outlet port.
2. Unscrew nut (3), remove the crankcase
breather and discard it.
3. Fit a new crankcase breather and secure the
rubber pipe with the hose clamp.
870984-01 95