EasyManua.ls Logo

Bender RCMA423-DM - Page 41

Bender RCMA423-DM
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
41
RCMA423-DM_D00064_03_M_XXEN/06.2017
Inputs/outputs
Cable length for external test/reset button ................................................................................................... 0…10 m
Voltage output
Open circuit voltage (terminals open)........................................................................................................... ≤ DC 20 V
Voltage output........................................................................................................................................... DC 0…10 V
Load...................................................................................................................................................................... ≥ 1 kΩ
Resolution ..............................................................................................................................................................50 mV
Tripping time 1 x I
Δn
.............................................................................................................................................> 1.8 s
Tripping time 5 x I
Δn
........................................................................................................................................> 360 ms
Current outputs:
Short-circuit current ......................................................................................................... ≤ 30 mA, short-circuit proof
Current output....................................................................................................... DC 0/4…20 mA
Load.................................................................................................................................................................... ≤ 500 Ω
Resolution .............................................................................................................................................................0.1 mA
Tripping time 1 x I
Δn
.............................................................................................................................................> 1.8 s
Tripping time 5 x I
Δn
........................................................................................................................................> 360 ms
Current output ...................................................................................................................................... DC 0…400 μA
Load................................................................................................................................................................. ≤ 12.5 kΩ
Resolution .................................................................................................................................................................2 μA
Tripping time 1 x I
Δn
.............................................................................................................................................> 1.8 s
Tripping time 5 x I
Δn
........................................................................................................................................> 360 ms
Environment/EMC
EMC .................................................................................................................................................................. IEC 62020
Operating temperature....................................................................................................................... -25 ºC…+55 ºC
Classification of climatic conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) .........................................................3K5 (except condensation and formation of ice)
Transport (IEC 60721-3-2).................................................................2K3 (except condensation and formation of ice)
Storage (IEC 60721-3-1)....................................................................1K4 (except condensation and formation of ice)
Classification of mechanical conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) ............................................................................................................................... 3M4
Transport (IEC 60721-3-2)...................................................................................................................................... 2M2
Long-term storage (IEC 60721-3-1)....................................................................................................................... 1M3

Table of Contents