GrandPrix (GP-7 Series) Two-Post Lifts 30 P/N 5900209August 2018 — Rev. C2
Tip The Power Unit is heavy. It is best to have one person hold the Power Unit in place while
a second person does the bolting.
4. Push the bolt through the Powerside Post and the spacer, into the threaded hole on the back of
the Power Unit.
5. Secure the bolt.
6. Repeat for the second bolt.
7. Fill the reservoir with approved fluids.
The reservoir holds approximately 3.7 gallons (14 litres). Use care to keep the fluid clean when
filling the reservoir.
Approved fluids are any general purpose ISO-32, ISO-46, or ISO-68 hydraulic oil or approved
automatic transmission fluids such as Dexron III, Dexron VI, Mercon V, Mercon LV, or any synthetic
multi-vehicle automatic transmission fluid.
Important: Do not connect the Hydraulic Lines to the Power Unit at this time.