HD-973P Series Multi-Level Parking Lift 18 P/N 5900076Rev. B3 — January 2024
CAUTION BendPak lifts are supplied with installation instructions and concrete anchors that
meet the criteria set by the American National Standard “Automotive Lifts Safety
Requirements for Construction, Testing, and Validation,” ANSI/ALI ALCTV. You are
responsible for any special regional structural and/or seismic anchoring
requirements specified by any other agencies and/or codes such as the Uniform
Building Code (UBC) and/or International Building Code (IBC).
Be sure to check the floor to determine if it is a post-tension slab. In this case, you must
contact the building architect before drilling. Using ground penetrating radar may help you find the
tensioned steel.
WARNING Cutting through a tensioned cable can result in injury or death. Do not drill into a
post-tension slab unless the building architect confirms you are not going to hit
tensioned steel, or you have located it using ground penetrating radar. If colored
sheath comes up during drilling, stop drilling immediately.
Multi-Lift Installations. For a Multi-Lift setup, there must be a minimum spacing of 5 inches
from the edge of the Baseplate to the edge of the Baseplate on the next Lift.
CAUTION Installing a Lift closer than 5 inches to the edge of the Baseplate on the next Lift
compromises the holding strength of the Anchor Bolts, which puts anyone near the
Lifts in danger.