PL-12000DP Series Parking Lift 40 P/N 5900285 — Rev. A1 — February 2023
3. Connect the various pieces of Tubing to the Tee Compression Fittings on the Lift, making sure to
route the Tubing section through the Retaining Rings along the inside of the Runway.
Make sure to position the Tee Compression Fittings as shown in the drawing
.
⚠ WARNING Make sure to route the Tubing sections on the
outside
ends of the Front and Rear
Crosstubes through the Steel Tubes on the ends of the Crosstubes. This keeps the
Tubing and the Tee Connectors from being disturbed as the Lift is used. This is
important, because if the Air Lines are accidently pulled, the Safety Locks on the
Lift may not work correctly. If the Tubing has become disconnected from a Tee
Fitting, take the Lift out of service, and repair the Air Lines.
Refer to Working with Compression Fittings and Tubing for more information about
connecting the Tubing to the Tee Compression Fittings.
4. Leave the Power Unit end of the Air Line hanging out of the Flex Tube opening for now. The Flex
Tube, and the Air Line will be connected to a Tee Fitting and the Pushbutton Air Valve later in the
procedure.