PL-12000DP Series Parking Lift 67 P/N 5900285 — Rev. A1 — February 2023
Maintenance
⚠ DANGER Before performing any maintenance on your Lift, make sure it is completely
disconnected from power. Do not reconnect it until all maintenance procedures are
safely finished. The Lift uses electrical energy; if your organization has
Lockout/Tagout policies, make sure to implement them
before
performing any
maintenance. If you come into contact with high voltage/current, you may be
injured or killed.
If worn, damaged, or broken parts need replacement,
ONLY
use parts from (or approved by) the
original equipment manufacturer (OEM) or parts that meet the OEM’s specifications.
⚠ WARNING If non-approved parts are installed, including those that do not meet the
specifications of the original equipment manufacturer, you void your warranty and
compromise the safety of everyone who installs or uses the Lift.
To maintain your Lift:
• Daily: Keep the Lift clean. Wipe up any spills, clean any dirt.
• Daily: Make a visual inspection of all moving parts and check for damage or excessive wear.
Replace any damaged or worn parts before using the Lift.
⚠ DANGER Do not use the Lift if the Lifting Cables are damaged or extremely worn. If a Vehicle
is raised and damage or extreme wear is noticed, very carefully lower the Vehicle to
the ground; if this can be done safely. If it cannot be done safely, evacuate the area
and make arrangements with trained lift service personnel to lower the Vehicle.
When the Lift is on the ground, take it out of service, disconnect it from power, and
make arrangements with trained lift service personnel to fix the damage and/or
wear.
• Daily: Make sure the Safety Lock is working correctly.
⚠ WARNING Do
not
use a Platform if its Safety Lock is damaged or excessively worn.
• Weekly: Check all Controls, including the Emergency Stop, to make sure all are functioning.
• Weekly: Check all Labels on the Lift. Replace them if they are illegible or missing.
• Monthly: Check Hydraulic Fluid levels. Refill if low.
• Monthly: Check Cable connections, bolts, and pins for proper mounting and torque.
• Every two months: Check all Anchor Bolts to make sure they are correctly tightened. If they are
not, retighten them.
• As needed. Take the Lift out of service and then replace the Lifting Cables if there are signs of
damage or extreme wear.
⚠ WARNING Do not operate the Lift if there are maintenance issues; instead, take the Lift out of
service, then contact the dealer, visit bendpak.com/support, email support@bendpak.com, or
call (800) 253-2363.