PL-12000DP Series Parking Lift 64 P/N 5900285 — Rev. A1 — February 2023
• Check the Hydraulic Fluid reservoir; it must be full of approved Hydraulic Fluid or automatic
transmission fluid. Th
e motor may be harmed by operating without adequate fluid.
• Check the Hydraulic System for leaks. Verify all Hydraulic Hose connections, Hydraulic Fittings,
and Auxiliary Port Plugs on the Lift and Power Unit are tight.
• Check the Platform Sections to verify they are tightly bolted and in place.
• Make sure all Posts are properly anchored, shimmed, level, and stable.
• Make sure all Cables are taut, correctly routed and properly positioned in their Sheaves, and
lubricated.
• Verify that all Safety Locks are working normally.
• Make sure a copy of the Installation and Operation Manual is left with the Lift.
• If it has not been done already, perform an operational test of the Lift. Refer to Performing an
Operational Test.