LIFT WILL NOT STAY UP
POSSIBLE CAUSE
1. Air in oil, (1,2,3)
2. Check valve leaks, (6)
3. Cylinders leak internally, (7)
4. Lowering valve leaks, (4,5,1,7,6)
5. Leaking  ttings, (8)
REMEDY INSTRUCTION
1. Check oil level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The oil level should be up to the bleed screw in the
reservoir with the lift all the way down.
2. Oil seal damaged and cocked . . . . . . . . . . . . . . . . . . . . . . . . Replace oil seal around pump shaft.
3. Bleed cylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Refer to Installation Manual.
4. Flush release valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hold release handle down and start unit allowing it to
run for 15 seconds.
5. Replace with new valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replace with new valve.
6. Return unit for repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Return unit for repair.
7. See Installation Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contact BendPak Customer Support.
8. Check complete hydraulic system for leaks. . . . . . . . . . . . . . Tighten all hydraulics  ttings and inspects all hoses.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BendPak XPR-10 and is the answer not in the manual?

BendPak XPR-10 Specifications

General IconGeneral
Capacity10, 000 lbs
Lift TypeTwo-Post Lift
Lifting Time45 seconds
Voltage220V
Minimum Height4.5 inches
Max Lift Height69 inches
Power Requirements220 VAC / 60 Hz / 1 Ph
Overall Height145" / 3683 mm

Related product manuals