40
Multifunction Control Panel
Setting up Teleservice and Test Event
1. Enter Parameter Number 283, then press E.
2. Using keys
3 and/or 5, enable/disable the “Callback” and “Double
Call” options (refer to Tab. 11 for details).
3. Press E to confirm, or e to abort the setting.
1. Enter Parameter Number 281, then press E.
2. Enter the required number of rings (accepted entries: 0 through 19).
3. Press
E to confirm, or e to abort the setting.
1. Enter Parameter Number 282, then press
E.
2. Enter the Telephone number ID number (refer to Tab. 11 for details).
3. Press E to confirm, or e to abort the setting.
1. Enter Parameter Number 286, then press
E.
2. Using key
8, enable/disable the Test Call (refer to Tab. 11 for details).
3. Press E to confirm, or e to abort the setting.
1. Enter Parameter Number 300, then press E.
2. Enter the Date and time of the Test Event in DDMMYYHHMM format
(10 digits), for example, to set 3rd May 2004 enter 030504.
3. Press
E to confirm, or e to abort the setting.
1. Enter Parameter Number 304, then press
E.
2. Enter the number of hours between each Test Event (accepted entries: 1
through 9999). To disable the ‘Interval’, enter 0 (zero).
3. Press E to confirm, or e to abort the setting.
Callback and
Double Call
Number of Rings
Installer Telephone
Number
(11/5*'%/'







 

! "
728/2!////
728/2!/
+
#$ %
#
#
& '

(# )
+
&*( 
9! ::;;
+
 
72.#02
Test Call
First Test Event
Interval