32
Multifunction Control Panel
Setting up the Zones
1. To set up the Type and Balance, enter a Parameter Number from 163 – 191
(refer to Tab. 7a for details), then press
E.
NOTE: At this point, keys
1 to 5 will allow you to program the Zone Type and
Balance (refer to “Meaning of LED/Key status” in Tab. 7a).
2. Using keys
1 to 3, select the Zone Type.
3. Using keys 4 and/or 5, select the Balance Type.
4. Press
E to confirm, or e to abort the setting.
1. To assign the Zone Attributes, enter a Parameter Number from 164 – 192
(refer to Tab. 7a for details), then press
E.
NOTE: At this point, keys
1 to 8 correspond to Zones 1 to 8.
2. Using the respective key, assign the Zone Attribute (refer to Tab. 7a for
details).
IMPORTANT - Ensure that you DO NOT press keys 7 and 8 contempo-
rarily.
3. Press
E to confirm, or e to abort the setting.
Setting up the
Type and Balance
Zone Attributes
NOTE: The ON, OFF, Slow or Fast Blinking status of each key determines
the status the respective Partition will adopt during A Mode (refer to “Mean-
ing of LED/Key status” in Tab. 6).
3. Press
E to confirm, or e to abort the setting.
NOTE: The Reader will not accept “Z” Mode (Stay with 0 Delay).
1. To set up the B Mode Arming configuration, enter a Parameter Number
from 24 – 159 (refer to Tab. 6 for details), then press
E.
2. Using keys
1 to 4 (respectively Partitions 1 to 4), set up the B Mode
Arming configuration.
NOTE: The ON, OFF, Slow or Fast Blinking status of each key determines
the status the respective Partition will adopt during B Mode (refer to “Mean-
ing of LED/Key status” in Tab. 6).
3. Press
E to confirm, or e to abort the setting.
NOTE: The Reader will not accept “Z” Mode (Stay with 0 Delay).
B Mode Arming