7 Bentone BFG 1
2.3 Gas categories, approved gases
Components are approved for dry biogas with a maximum content of 0.1% H
2
S.
2.2 Capacity range
Measurements according to EN 15036-1:2006
Alt.1 The noise level of the burner can be reduced by equipping the burner
with silencer. Installation must be done so it does not prevent air supply
to the burner.
Alt.2 The burner’s noise level can be reduced by connecting the burner’s air
intake to the air duct that opens into an appropriate location. Installation
must be done so it does not prevent air supply to the burner.
2.4 Technical specication
BFG 1
Main supply 230V, 1~, 1.7A, 50/60Hz, IP20
Max fuse rating 6.3A
NO
X
-class 2
Noise level 75dBA
Category Country of destination Supply pressure
II
2R3R
AT, BE, BG, CH, CY, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HR, HU, IE,
IS, IT, LT, LU, LV, MK, MT, NL, NO, PL, PT, RO, RS, SE, SI, SK, TR
20 mbar
II
2H3B/P
AT, CH, CY, DK, FI, LT, RO, SE, SK 20 mbar
II
2H3P
GB, IE 20 mbar
II
2L3B/P
RO 20 mbar
II
2E3B/P
PL 20 mbar
I
2E(R)B
BE 20 mbar
I
3P
BE 20 mbar
II
2EK3B/P
NL 20 mbar
160302-302-5
BFG 1-2 H3
G20  25 -100 2.6 10.6 360
G25  25 - 100 3.1 12.3 360
G30  37 - 100 1.1 3.1 360
G31  37 - 100 1.5 4.1 360
    25 - 80 4.2 13.3 360
160303-770-1
Capacity
kW
Gas quantity
at min. power
Nm
3
/h
Gas quantity
at max. power
Nm
3
/h
Max.
connection
pressure mbar
Min
connection
pressure mbar
See data plate.
Biogas
Gas quantity and capacity vary according to grade of gas and connection pressure.